Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
São Paulo med. j ; 142(4): e2023177, 2024. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1536907

ABSTRACT

ABSTRACT BACKGROUND: Contamination of the breathing circuit and medication preparation surface of an anesthesia machine can increase the risk of cross-infection. OBJECTIVE: To evaluate the contamination of the anesthetic medication preparation surface, respiratory circuits, and devices used in general anesthesia with assisted mechanical ventilation. DESIGN AND SETTING: Cross-sectional, quantitative study conducted at the surgical center of a philanthropic hospital, of medium complexity located in the municipality of Três Lagoas, in the eastern region of the State of Mato Grosso do Sul. METHODS: Eighty-two microbiological samples were collected from the breathing circuits. After repeating the samples in different culture media, 328 analyses were performed. RESULTS: A higher occurrence of E. coli, Enterobacter spp., Pseudomonas spp., Staphylococcus aureus, and Streptococcus pneumoniae (P < 0.001) were observed. Variations were observed depending on the culture medium and sample collection site. CONCLUSION: The study findings underscore the inadequate disinfection of the inspiratory and expiratory branches, highlighting the importance of stringent cleaning and disinfection of high-touch surfaces.

SELECTION OF CITATIONS
SEARCH DETAIL